You are using an outdated browser Internet Explorer. It does not support some functions of the site.

Recommend that you install one of the following browsers: Firefox, Opera or Chrome.

Contacts:

+7 961 270-60-01
ivdon3@bk.ru

  • Increase of efficiency of a desulfurization of flue gases by limy milk on the basis of anolyte

    Results of researches of increase of efficiency of a desulfurization of domestic thermal power plants are reflected in article. Reduction of emissions of dioxide of sulfur due to use of the oversaturated water solutions at dissolution of not extinguished lime anolyte will allow to reduce emissions in the atmosphere on average to 1042,48 tons/year on one 300 MW power unit.

    Keywords: issue, desulfurization, sulfur oxide, power unit, anolyte, catholyte, activation, solubility, electrochemical processing, gas mix