  • Study of the thermal performance of plate heat exchangers operating in a hot water supply circuit under conditions of combined operation with a storage tank

    The article discusses the issues associated with the preparation of hot water in individual apartment heating systems that use a secondary plate heat exchanger of the boiler. The drawbacks of this approach are highlighted, including delays in hot water supply, the need to drain water from the pipeline, the inability to regulate temperature and flow rate, as well as the lack of recirculation capabilities. As an alternative, a system with a storage tank and a plate heat exchanger is proposed, which ensures stable water temperature, adjustable flow rate, resource savings, and the possibility of recirculation. Based on experimental studies, the heat transfer coefficient for heat exchangers with profiled and flat plates has been determined. Calculations of the required heat exchanger area are provided, depending on the type of plates, the volume of the storage tank, and its charging time, which allows for the optimization of hot water supply system design.

    Keywords: plate heat exchanger, storage tank, heat transfer coefficient