Comparative analysis of the efficiency of the use of caisson Skydome in modern multistory buildings with the standard columns step

Abstract

Comparative analysis of the efficiency of the use of caisson Skydome in modern multistory buildings with the standard columns step

Suhareva A.V., Aksenov V.N.

Incoming article date: 14.12.2016

The market in Russia is common formwork caisson ceilings SkyDome system.In the article the question of the effectiveness of ribbed caisson ceilings in multi-storey monolithic buildings compared to with .flat slab floor. The program complex "Lira-CAD 2013" calculated the 18-storey residential buildings with monolithic framework. Consider in detail the reinforcement floors typical floor in two versions: a flat of 200 mm and a caisson plate of 50 mm and beams with a section of 200х350 mm with a step of 900х900 mm. Analysis of the results showed that in a building with columns a step of about 5 m difference in cost of materials for the manufacture of the overlap was about 1%. Efficiency gains are expected by increasing the span up to 8 ... 10 m

Keywords: caisson, flat slab floor,monolithic framework, modular falsework of SkyDome, structural calculation, LIRA-CAD