Features of calculation and reinforcement of the foundations of the distribution center building in conditions of weak soils

Abstract

Features of calculation and reinforcement of the foundations of the distribution center building in conditions of weak soils

"Podtelkov V.V., Prokopenko A.V., Zelenkov D.S., Pshidatok M.A"

Incoming article date: 14.02.2025

The cargo turnover of modern distribution centers of network operators reaches hundreds of thousands of tons per year. The technological load on the floors in the warehouse part of the building is 8-10 t/m2 (80-100 kPa), on the floors – up to 2.4 t/m2 (24 kPa). These loads transfer significant pressure through the foundations of the frame to the ground, which, with large sole sizes and mutual influence, increases the lower boundary of the compressible thickness and, as a result, the draft of structures. In the presence of weak soils at the base, precipitation reaches exorbitant values. The situation is aggravated by the high groundwater level, which also increases the sedimentation of foundations. The article presents and analyzes options for solving the problem by strengthening the base by compacting the top layer and cementing it to different depths depending on the pressure and construction of the foundation.

Keywords: reinforcement of the base, recycling, permissible calculated precipitation, calculated soil resistance