×

You are using an outdated browser Internet Explorer. It does not support some functions of the site.

Recommend that you install one of the following browsers: Firefox, Opera or Chrome.

Contacts:

+7 961 270-60-01
ivdon3@bk.ru

  • To research results of level's polution of the air at the area of location of gas feeling station to decrease exhaust of hydrocarbons' vapors

    The article is devoted to the issue of improving the environmental safety of highly urbanized territories. The article presents the results of field measurements of pollutants into the atmosphere from gas stations within the urbanized territories of cities of the Russian Federation. The largest part of the allocation of oil product vapors entering the local aspiration systems is associated with the operations of filling and emptying fuel storage tanks at gas stations. The results of field measurements of the values of hydrocarbon concentrations obtained on the basis of the values of maximum permissible concentrations of ingredients are presented. The conclusion is drawn on the feasibility of environmental protection measures to reduce emissions when finding housing in the border area of the sanitary protection zone (SPZ) of gas stations. To reduce emissions from gas station sources, it was proposed to equip the gas aspiration system of the gas feeling tank with an improved design of the absorption device. In order to reduce waste generation as a working agent in such devices, it was proposed to use wastewater with a certain amount of oil products from a local gas station treatment device. This approach also allows to reduce the negative anthropogenic impact of gas stations in terms of the formation of additional amounts of waste generated during their operation. Successful tests have shown reliable and efficient operation of the pilot plant with the proposed apparatus.

    Keywords: gas station, gasoline, emission, atmosphere, concentration, hydrocarbons, aspiration, reservoir, pollution, oil product, pollution, water

  • Microbiological research of fine dust in air conditioners of office buildings

    Data on the effect on human health of dust from office air conditioners are presented. The microbial and dispersion composition of dust has been studied. Studies have shown that the microbial number in the rooms depends on the floor on which the air conditioner is installed. Also, the presence of large fractions of dust decreases with increasing height at which the air conditioner is installed.

    Keywords: air pollution, dispersion analysis, air conditioning systems, human health,bacteria, mukor, aspergillus, penicillium